28
EN
IP2163EN
Display Description
CA - Setting the maintenance alarm
(factory setting - alarm disabled: 0.0 00. 00).
You can set the required number of operations (regarding the partial opera-
tions counter) for signalling the maintenance alarm.
When the set number of operations is reached, the alarm message appears
on the display .
[esempio]
→→→→→
[esempio]
→→→→→
→→ (00) (07) (00) → 700 manovre [esempio]
2”
OA - Selecting maintenance alarm display mode.
00 - Indication on display (alarm message ). The
yellow LEDs come on permanently (see table on
page 13).
01 - Indication on flashing light (with the automation
stopped, it flashes 4 times keep happening every
hour) and display (alarm message ). The yel-
low LEDs come on permanently (see table on
page 13).
02 - Indication on gate open indicator light (with the
automation closed, it flashes 4 times keep hap-
pening every hour) and display (alarm message
). The yellow LEDs come on permanently (see
table on page 13).
ZP - Zero-setting of partial operations counter.
→
2”
For correct functioning, you are advised to reset the partial operations counter:
- after maintenance work;
- after setting the maintenance alarm interval.
7.9.1 Additional CC level parameters that can be configured
(available with → enabled)
(example)
(example)
operations (example)
CC - Cycles counter