4
EN
IP2163EN
3. Technical specifications
NOTE: the given operating and performance features can only be guaranteed with the
use of DITEC accessories and safety devices.
1.1 Safety functions
The CS12M control panel has the following safety functions:
- obstacle recognition with force limiting;
The maximum response time of the safety functions is 0.5 s. The reaction time to a faulty safety
function is 0.5 s.
The safety functions comply with the standards and performance level indicated below:
EN ISO 13849-1:2008 Category 2 PL=c
EN ISO 13849-2:2012
The safety function cannot be bypassed either temporarily or automatically. Fault exclusion
has not been applied.
The manufacturer Entrematic Group AB, with headquarters in Lodjursgatan 10, SE-261 44 Land-
skrona, Sweden, declares that the Ditec CS12M type control panel complies with the condi-
tions of the following EC directives:
2014/30/EU (EMCD)
2014/35/EU (LVD)
2014/53/EU (RED)
L a n d s k r o n a , 2 0 2 0 - 1 1 - 2 6 M a t t e o F i n o
President & CEO)
2. EC Declaration of Conformity
nt
NES300EHP NES400EHP NES600EHP NES600EHP
Power 230V~ 50/60Hz 230V~ 50/60Hz 230V~ 50/60Hz 230V~ 50/60Hz
Motor output 24V
12A max 24V 14A max 24V 16A max 24V 20A max
Power supply for
accessories
24V
0,3A max 24V 0,3A max 24V 0,3A max 24V 0,3A max
Usage temperature
-20°C +55°C
-20°C +55°C
-20°C +55°C
-20°C +55°C
Storable radio codes
100
200 [BIXMR2]
100
200 [BIXMR2]
100
200 [BIXMR2]
100
200 [BIXMR2]
Radio frequency 433,92MHz 433,92MHz 433,92MHz 433,92MHz