12. Examples of application for parallel
automations
A B
With the parallel connection, the opening,
closing, reopening when an obstacle is en-
countered during closing and flashing of flash-
ing lights are synchronised.
The obstacle during opening and safety devices
(safety edges) must be installed each one on its
own door and act independently of each other.
Establish which one is the MASTER automa-
tion and which one is the SLAVE automation.
The MASTER automation could be the one you
decide to open partially (1-20 connected).
1. Disconnect connectors 1-G1-G3 from the
control panels.
2. Set the following parameters on both auto-
mations via the display:
Setting advanced parameters
>
→
2”
Setting input mode
> >
Setting automation parallel mode
> >
Set > > .
NOTE: if > , if one door is closed and the
other is closing, a command 1-8 causes the
movement of the moving door to stop with-
out reopening the closed door.
You are advised NOT to change the setting
of parameter > > .
3. Reconnect connectors 1-G1-G3.
4. Enable automatic closing only on the MASTER automation with > > . or with >
> (if you want to use a timer).
5. Set the desired automatic closing time ( > ) on the MASTER automation high enough to
allow the SLAVE automation to fully open.
With these settings the automations will perform the closing operation at the same time as the
time set with the MASTER automatic TC expires).
6. Install only one ZENRS radio receiver - ZENPRS on the MASTER automation.
UP
DOWN
AUXAUX
ENTER
ESC
016 0 1 1 1
G1 G3
234913520
+LP-
18
RDX
Automatic external
closing
Step-by-step
Partial opening
Opening
Closure
Stop
GOLR
GOL868R
-
+
24V output
Safety reopening
Safety stop
Flashing light
Automation status
lamp
UP
DOWN
ENTER
ESC
016 0 1 1 1
G1 G3
234913520
+LP-
18
RDX
-
+
24V output
Safety stop
Flashing light
Automation status
lamp
CS12M Master
CS12M Slave
SOF / GOPAVSOF / GOPAV