Problem Possible cause Signal /
Alarm
Operation
The external safety devices
are not activated.
Incorrect connections be-
tween the photocells and the
control panel.
Check that
/ is dis-
played
Connect NC safety contacts
together in series and remove
any jumpers on the control
panel terminal board.
Check the
and
setting
The automation opens/clos-
es briefly and then stops.
There is a presence of friction. Manually check that the auto-
mation moves freely and check
the
/ adjustment
Contact Technical Service
The remote control has lim-
ited range and does not work
with the automation moving.
The radio transmission is im-
peded by metal structures and
reinforced concrete walls.
Install the antenna outside.
Replace the transmitter bat-
teries.
The remote control does not
work
No storage module or incor-
rect storage module.
Switch the automation off and
plug in the correct storage
module.
Check the correct memorisa-
tion of the transmitters on the
built-in radio. If there is a fault
with the radio receiver that is
built into the control panel, the
remote control codes can be
read by removing the storage
module.
The flashing light is not
working
Bulb burnt or flashing light
wires detached or short-cir-
cuited.
Check the bulb and/or wires.
Contact Technical Service
The "gate open" indicator
light doesn't work
Bulb burnt or wires detached
or short-circuited.
Check the bulb and/or wires.
Contact Technical Service