No. Alert Text Alert Level Description
6220 Logging directory almost
full
Alarm
(Red Alert)
Error saving the logging file.
Remedial action: Make space on the
internal hard drive.
6221 Error writing logging file Alarm
(Red Alert)
Error saving the logging file.
Remedial action: Make space on the
internal hard drive.
6222 Error writing logging copy
file
Warning
(Amber Alert)
Error saving the logging copy file.
Remedial action: Make space on the
internal hard drive.
6251 Font style (bold or italic) is
invalid)
Warning
(Amber Alert)
Invalid font style.
Remedial action: Allocate the Italic or
Bold font in the controller.
11050 Failed to writing cfr log Alarm
(Red Alert)
Error while saving CFR log.
Remedial action: Make space on the
CFR partition.
General System Alerts
No. Alert Text Alert Level Description
11015 Insucient RAM to create
text
Alarm
(Red Alert)
There is insucient RAM to create text.
Remedial action: Restart the controller.
Contact your local support oce if the
problem continues.
11016 Formal error in text file Alarm
(Red Alert)
Error in the language file.
Remedial action: Check and correct the
language file.
11051 Initializing the RTC clock Alarm
(Red Alert)
System clock reset with backup battery
running out.
Remedial action: Reset the system
clock. Contact your local support oce
for battery replacement.
OPERATION
EPT053091 - Issue 5 - 07 May 2021 184

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Domino Gx-Series and is the answer not in the manual?

Domino Gx-Series Specifications

General IconGeneral
BrandDomino
ModelGx-Series
CategoryController
LanguageEnglish

Related product manuals