EasyManuals Logo

DSC Neo User Manual

DSC Neo
236 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
Section 5: Programming
l zone 001 128
l keypad 01 16
l siren 01 16
l repeater 01 08
OFF does not activate if a device tamper condition is present.
12 RF Delinquency
ON: activates if any of the following RF delinquency troubles is detected:
l zone 001 128
l keypad 01 16
l siren 01 16
l repeater 01 08
OFF does not activate if an RF delinquency condition is present.
13 Module Supervisory
ON activates if any of the following module supervisory troubles is detected:
l HSM2HOST
l keypad 01 16
l zone expander 01 15
l HSM2204 1 4
l HSM2300 1 4
l HSM2208 01 16
OFF does not activate if a module supervisory trouble is detected.
14 Module Tamper
ON activates if any of the following module tamper conditions is present:
l HSM2HOST
l Keypad 01 16
l Zone expander 01 15
l HSM2204 1 4
l HSM2300 1 4
l HSM2208 01 16 tamper troubles
OFF does not activate if a module tamper condition is present.
15 Communications
ON activates if any of the following communications conditions is present:
l TLM trouble
l FTC receiver 1 4
l SIM Lock trouble
l Cellular Trouble
l Ethernet Trouble
l Receiver 1 4 absent
l Receiver 1 4 supervision trouble
l SMS Configuration trouble
l Alt comm. Fault.
OFF does not activate if a communications trouble condition is present.
16: Not Networked
ON activates if any of the following not networked conditions is present:
l Zone 001 128
l Keypad 01 16
l Siren 01 16
l Repeater 01 08
l User 01 95 (wireless keys) not networked troubles
OFF does not activate if a not networked trouble condition is present.
156 Latched System Event
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
- 82 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes