EasyManua.ls Logo

DSC Neo - Page 83

DSC Neo
236 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 5: Programming
OFF: activated during normal operation. Deactivated when triggered.
02 Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
04 Fire Alarm
ON: activates with fire alarm, [F] key, fire zones, 2-wire smoke.
OFF: does not activate with fire alarm.
05 Panic Alarm
ON: activates on panic alarm (audible or silent).
OFF: does not activate on panic alarm.
06 Burglary Alarm
ON: activates on burglary alarm.
OFF: does not activate on burglary alarm.
07 Medical Alarm
ON: activates on medical alarm.
OFF: does not activate on medical alarm.
08 Supervisory
ON: activates on supervisory alarm.
OFF: does not activate on supervisory alarm.
09 Priority Event
ON: activates on priority alarm.
OFF: does not activate on priority alarm.
10 Holdup
ON: activates on holdup alarm.
OFF: does not activate on Holdup alarm.
11 Duress Alarm
ON: activates on duress alarm.
OFF: does not activate on duress alarm.
12 Emergency Alarm
ON: activates on emergency alarm.
OFF: does not activate on emergency alarm.
13 Fire Supervisory
ON: activates on fire supervisory alarm.
OFF: does not activate on fire supervisory alarm.
14 Fire Trouble
ON: activates on fire trouble condition.
OFF: does not activate on fire trouble condition.
15– CO Alarm
ON: activates on CO alarm.
OFF: does not activate on CO alarm.
157 System Tamper
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
09 System/Module Tampers
ON: activates when any module tamper condition occurs.
- 83 -

Table of Contents

Related product manuals