Section 5: Programming
OFF: activated during normal operation. Deactivated when triggered.
02 Timed Output / Latched Output
ON: output remains active until the PGM output timer expires.
OFF: output remains active until an access code has been entered.
04 Fire Alarm
ON: activates with fire alarm, [F] key, fire zones, 2-wire smoke.
OFF: does not activate with fire alarm.
05 Panic Alarm
ON: activates on panic alarm (audible or silent).
OFF: does not activate on panic alarm.
06 Burglary Alarm
ON: activates on burglary alarm.
OFF: does not activate on burglary alarm.
07 Medical Alarm
ON: activates on medical alarm.
OFF: does not activate on medical alarm.
08 Supervisory
ON: activates on supervisory alarm.
OFF: does not activate on supervisory alarm.
09 Priority Event
ON: activates on priority alarm.
OFF: does not activate on priority alarm.
10 Holdup
ON: activates on holdup alarm.
OFF: does not activate on Holdup alarm.
11 Duress Alarm
ON: activates on duress alarm.
OFF: does not activate on duress alarm.
12 Emergency Alarm
ON: activates on emergency alarm.
OFF: does not activate on emergency alarm.
13 Fire Supervisory
ON: activates on fire supervisory alarm.
OFF: does not activate on fire supervisory alarm.
14 Fire Trouble
ON: activates on fire trouble condition.
OFF: does not activate on fire trouble condition.
15– CO Alarm
ON: activates on CO alarm.
OFF: does not activate on CO alarm.
157 System Tamper
01 True Output/Inverted
ON: deactivated during normal operation. Activated when triggered.
OFF: activated during normal operation. Deactivated when triggered.
09 System/Module Tampers
ON: activates when any module tamper condition occurs.
- 83 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes