1-3
Chapter1 Before Use
No. Name Operation
[1] Control panel For details, refer to “3. Names and Operation of Control Panel” (p.1-4).
[2] Horizontal conveyance section Conveys the collated paper.
[3] Emergency stop switch Press this switch to stop operations in emergency. Normally, use the stop key
on the control panel to stop operations.
[4] Main power switch When pressed, the power turns ON and the machine sets into the standby
state.
[5] Power switch When connecting and using several towers together, the power of all the
towers can be turned ON and OFF using the switch of the rst tower (the
leftmost tower).
[6] Reject tray When feed error occurs, defected sets are ejected to this tray.
[7] Lifting unit Conveys the collated paper to the downstream unit.
[8] Hand marry Set paper here when feeding paper manually. Enables manual feed of set
consisting of up to 10 sheets of paper at a time.
[9] Vertical conveyance board Conveys the fed paper.
[10] Sub-guide Presses the edge of the paper being conveyed to prevent the paper from
rising.
[11] Long stack guide Used to feed paper of A4 size or more (paper length: 300 mm / 11.8 inches).
[12] Separator adjusting knob Used to adjust the position of the separator.
[13] Paper guide Presses the edge of the paper to hold the paper in place.
[14] Paper feed tray Used to load paper to be collated.
[15] Separating-air duct Blows out the air for separating paper loaded to the paper feed tray.
[16] Separator Used to prevent double-feed.
[17] Suction belt Sucks and conveys the paper.
[18] Level sensor Determines the height (interval between the paper and suction belt) of the
paper oated by the separating air.
[19] Level sensor adjusting knob Adjusts the interval between the paper and suction belt.
[20] Shutter Adjusts the amount of separating air blown out.
[21] Separating-air adjusting knob Used to adjust the position of the shutter.
[22] Suction box shutter bar Adjusts the range of suction.
[23] Separating-air adjusting lever Adjusts the strength of separating air.
[24] Extension tray Used to load paper of 508 mm / 20.0 inches or longer (*1) by pulling out.
[6] to [8] are collectively called LUL-HM. [6] to [8] are optional products.
(*1) : The following paper length and width can be used.
• Length: up to 610 mm / 24.0 inches
• Width: 200 to 230 mm / 7.87 to 9.06 inches
Name of collator (tower) connected
When using several towers together, the tower on the left side as seen from the control panel is Tower A and
those that follow are called Towers B, C, D, E, and F in order.
Tower A
Tower B Tower C Tower D Tower E
Tower F