EasyManua.ls Logo

DURKOPP ADLER 756 A

DURKOPP ADLER 756 A
498 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
Service Instructions 755 A/756 A - 00.0 - 02/2019 379
Loading process test
The display switches to Loading process test.
Fig. 346: Loading process test
The sewing material is fed through the sewing path without sewing
including all functions stored in the seam program.
The loading process test is designed to check if the flaps and piping strips
are transported correctly through the sewing path.
Information
To monitor the transport path of the sewing material, reduce the insertion
speed prior to the loading process test ( p. 330).
To perform a loading process test:
1. Press the Loading process test button.
The machine boots up.
2. Perform a reference run.
The insertion mode is active.
3. Insert the sewing material.
4. Press the pedal to close the transport clamp.
The display shows the message
.
5. Press the right pedal.
The loading process is completed without sewing by performing
pedal strokes.
6. To exit the test: access the menu Service > Machine test >
Machine workflow test again and press the button.

Table of Contents

Related product manuals