D 3.2 15
D_3.2_01_GB.fm 15-18
Central lubrication unit (o) (100)
The central lubrication unit turns on in
automatic mode when the drive engine
starts.
- Pumping time: 12 min
- Duration of the break: 2 h
m
It is prohibited to change the factory-set
durations of pumping and break without
consulting the technical customer serv-
ice!
A
Changing the duration of lubrication and
breaks may be necessary when placing
mineral or cement bound material mix.
Manual start of lubrication (pumping
time):
- Remove the cover lid (a).
- Keep the starting button (b) depressed for at least 2 sec.
- Replace the cover lid (a).
A
Observe the instructions of chapter „Maintenance“!