MGR10 A/B/C - Revision : I (for 7.0 software revision) 55
To change the value, press up/down arrow keys to select any of the 10 valid rates (MENU – Rem IO –
RS-232 –Baud rate). Pressing OK sets the chosen rate. Pressing Quit leaves it unchanged.
Valid rates are 75, 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200 Baud.
These set the Baud rate for both transmit and receive.
The data word format is fixed at;
Start bit; 1
Data word length; 8 bits
Parity checking; None
Stop bit; 1
Software handshaking using XON/XOFF is not implemented.