0 -10 Volts analog input output (03 OPTION ) 
 
This option allows the unit to deliver a proportional analog voltage to the displayed measurements on 
the  LCD  screen  (insulation  resistance,  test  voltages,  leakage  currents)  and  allows  controlling  the 
dielectric strength test high voltage by an  analog voltage between 0 and 10 volts. Jumpers for the 
setup of the board allow selecting different features. 
 
Specification 
 
  Output voltage  : from 0 to 10 VDC by 2.44 mV steps 
  Input voltage  : from 0 to 10 VDC 
  Output impedance  : 1 kohm ±5% 
  Input impedance   : 10 kohms ±5% 
  Insulation   : Not insulated, the ground is earthed 
  Connection   : screw terminal connector C6 on the rear panel 
 
0-10 volts input or output  
 
 
Board setup according to the unit models 
 
The board includes some jumpers described on the schematic underneath. These jumpers allow 
setup the board in a 2 analog outputs mode or in a 1 analog output + 1 analog input mode 
 
 
Fig 12.2