E L A N H O M E S Y S T E M S S1616A AMPLIFIER MODE
© ELAN Home Systems 2012 | All rights reserved.
Page 55
IR Control
Symptom
Possible Cause
Solution
IR Icon does NOT
flash when a button is
pressed.
1. IR controller not programmed or
programmed with a non-ELAN
command.
1. Program IR controller or correct programming.
2. S1616A not set to ELAN Mode
2. Set S1616A to ELAN Mode. (See page 23)
3. IR signal path wiring bad.
3. Verify IR signal path wiring. Check keypads, IR sensors, IR
distribution blocks, S1616A IR Input jack, IR emitters, etc.
No control of channel
from IR controller.
IR Icon DOES flash
when a button is
pressed.
1. Incorrect IR commands programmed
(not D16 commands).
1. Verify/correct IR programming.
2. Incorrect channel commands.
2. Verify/correct IR programming.
3. Channel range set incorrectly.
3. Change settings on the Channel Range Menu. (See page
34)
Intermittent control
from IR controller.
IR flooding.
Connect a “talk-back” emitter to the IR out of the S1616A.
Glowing or flickering when no commands are being sent indicates
IR flooding. Possible sources: ambient light or plasma / LCD TV
flooding.
Incorrect channel
and/or chassis
selected.
Incorrect S1616A IR commands
programmed.
Verify/correct IR programming.