12 technical data ems25
+
12.1 dimensional drawings:
Decorative trim kits must be ordered with ems25
+
controllers
12.2 controller relays:
ems25
+
maximum IEC rating @100-240VAC maximum UL ratings @ 120VAC
compressor 6(6)A, p.f. 0.6 6 FLA, 36 LRA
lights 2(2)A, p.f. 0.6 120VAC, 60Hz, 250W florescent
evaporator fan not applicable not applicable
12.3 temperature sensors:
sensor input range (
o
C) input range (
o
F)
appliance sensor
-10
o
C to 23.3
o
C
+/- 0.5
o
C
14
o
F to 74
o
F
+/- 1
o
C
gas cooler sensor
-10
o
C to 23.3
o
C
+/- 5
o
C
122
o
F to 257
o
F
+/- 10
o
F
12.4 environmental ratings:
characteristic value
IP (Ingress Protection):
l controller
IPX5
maximum ambient
temperature
55
o
C (131
o
F)
ems25+ and ems25advanced / General Use