MES3000 Ethernet switch series 145
rmon alarm index
mib_object_id interval
rthreshold fthreshold revent
fevent [type type] [startup
direction] [owner name]
index: (1..65535);
mib_object_id: valid
OID;
interval:
(1..4294967295)
seconds;
rthreshold:
(0..4294967295);
fthreshold:
(0..4294967295);
revent: (0..65535);
fevent: (0..65535);
owner name: string;
Default variable
collection method
absolute;
Default event
generation
instructionrising-
falling
Configure the alarm event trigger criteria.
- indexalarm event index
- mib_object_idvariable part identifier of the OID object
- intervaltime period when data is collected and compared to
rising and falling thresholds
- rthresholdrising threshold
- fthresholdfalling threshold
- reventevent index that is used for crossing the rising threshold
- feventevent index that is used for crossing the falling threshold
- typevariable collection and value calculation method for the
threshold comparison:
absolute methodabsolute value of the selected variable will be
compared to the threshold at the end point of the control interval
delta methodvalue of the variable collected in the last selection
will be deducted from the current value and the difference will be
compared to thresholds (the difference between the variable
values at the start point and the end point of the control interval)
- startupevent generation instruction at the first control interval
Define alarm event generation rules for the first control interval by
comparing the selected variable with the one of the thresholds or
both thresholds:
- risinggenerate a single alarm event for the rising threshold, if
the selected variable value at the first control interval is above or
equal to this threshold
- fallinggenerate a single alarm event for the falling threshold, if
the selected variable value at the first control interval is below or
equal to this threshold
- rising-fallinggenerate a single alarm event for the rising and/or
falling threshold, if the selected variable value at the first control
interval is is above or equal to the rising threshold/below or equal
to the falling threshold
- owner alarm event creator name
no rmon alarm index
Remove alarm event trigger criteria.
rmon table-size {history
history_entries | log
log_entries}
history_entries:
(20..32767)/270
log_entries:
(20..32767)/100
Specify the maximum size for RMON tables.
- history_entriesmaximum quantity of rows in the history table
- log_entriesmaximum quantity of rows in the record table
Value will take effect after the switch is restarted.
no rmon table-size {history |
log}
Restore the default value.
Ethernet interface configuration mode commands (interface range), port group interface
Command line request in Ethernet interface, port group interface configuration mode appears as
follows:
console(config-if)#
Table 5.157 Ethernet interface configuration mode commands, interface group
Command
Value
Action
rmon collection stats index
[owner name | buckets
bucket_num] [interval interval]
index: (1..65535);
name: valid string;
bucket-num:
(1..50)/50;
interval:
(1..3600)/1800 seconds
Enable history creation by statistics groups for the remote
monitoring database (MIB).
- indexrequired statistics group index
- namestatistics group owner
- bucket_numvalue associated with the quantity of cells for
statistics group history collection
- intervalpolling interval for history creation process
no rmon collection stats index
Disable history creation by statistics groups for the remote
monitoring database (MIB).
EXEC mode commands
Command line request in EXEC mode appears as follows: