MES3000 Ethernet switch series 111
Unidirection: not supported
Link monitor: supported
Remote loopback: supported
MIB retrieval: not supported
Mtu size: 1500
5.15.11 CFM protocol configuration
Ethernet CFM (Connectivity Fault Management), IEEE 802.1 ag enables monitoring, search and
troubleshooting in Ethernet networks; allows to control the connection, isolate the faulty network
segments and to identify the clients falling under networks restrictions.
Protocol uses the following terms:
Maintenance Domain (MD): a network segment which belongs to and managed by a single
operator.
Maintenance Association (MA): a collection of endpoints (MEP) with the same MAID
(Maintenance Association Identifier), which defines the type of service.
Maintenance association End Point (MEP): service endpoint located at its threshold.
Maintenance domain Intermediate Point (MIP): intermediate point for a domain.
Global configuration mode commands
Command line request in global configuration mode appears as follows:
console(config)#
Table 5.111 Global configuration mode commands
Command
Value/Default value
Action
ethernet cfm domain name
[level level]
name: (1..32)
characters;
level: (0..7)/0
Create (or change level) of CFM domain (MD) with the name and
enter the domain configuration mode.
- levelCFM domain level
no ethernet cfm domain name
Remove CFM domain (MD) with the name.
Domain configuration mode commands
Command line request in domain configuration mode appears as follows:
console(config-cfm-md)#
Table 5.112 CFM domain (MD) configuration mode commands
Command
Value/Default value
Action
id {dns dns | name name | id
mac mac_address number | id
null}
name: (1..43) characters;
dns: (1..43) characters;
mac_address: H.H.H or
H:H:H:H:H:H or
HHHHHH
number: (0..65535);
By default: id name
matches the domain name
Specify CFM domain (MD) identifier. Possible domain names:
- dnsdns name
- nametext string
- mac_address numberMAC address and domain numeric
identifier
- nullNULL identifier
no id
Set the default value.
service port { vlan-id vlan_id |
name name | number number}
vlan: (1..4094)
vlan_id: (1..4094)
name: (1..45) characters
Create CFM maintenance (MA) without VLAN association and
enter the maintenance configuration mode.
no service port
Remove CFM maintenance (MA).