112 MES3000 Ethernet switch series
service vlan vlan { vlan-id
vlan_id | name name | number
number}
Create CFM maintenance (MA) associated with VLAN (with 'vlan'
number) and enter the maintenance configuration mode. Possible
service names:
- vlan_id—VLAN number
- name—text string
- number—numeric identifier
Remove CFM maintenance (MA) associated with VLAN (with 'vlan'
number).
mip auto-create
[lowermeponly]
-/automatic creation is
disabled
Enable automatic creation of maintenance intermediate points
(MIP). Maintenance intermediate points (MIP) created on all
ports, where VLAN maintenance is defined.
Optional parameter 'lower-mep-only' allows to exclude ports,
where maintenance end point is created.
Restore the default value.
Maintenance configuration mode commands
Command line request in domain configuration mode appears as follows:
console(config-cfm-ma)#
Table 5.113 —CFM maintenance (MA) configuration mode commands
continuty-check interval
interval
interval: (1, 10, 100,
600)/1 second
Set the Continuty Check message sending interval.
no continuty-check interval
Set the downstream direction for the maintenance end point
(MEP).
Set the upstream direction for the maintenance end point (MEP).
Add the maintenance end point (MEP) with 'id' identifier to this
maintenance.
This command performs MEP association with the
maintenance only. MEP is created in the interface
configuration mode.
Remove maintenance end point (MEP).
mip auto-create
[{lowermeponly | none}]
-/The mode, configured
for domain with
existing maintenance, is
used by default
Enable automatic creation of maintenance intermediate points
(MIP). Maintenance intermediate points (MIP) created on all
ports, where VLAN maintenance is defined. Optional parameters:
- lower-mep-only—allows to exclude ports, where maintenance
end point is created
- none—disable automatic creation of maintenance intermediate
points (MIP)
Ethernet interface configuration mode commands
Command line request in Ethernet interface, port group interface configuration mode appears as
follows:
console(config-if)#
Table 5.114 —Ethernet interface configuration mode commands
ethernet cfm mep id
domain domain_name
service {vlan-id vlan_id |
name name | number
number}
id: (1..8191);
domain_name: (0..32)
characters;
vlan_id: (1..4094);
name: (0..45) characters;
Create maintenance end point (MEP) on the interface with 'id'
identifier for the selected maintenance in the specified domain
and enter the MEP configuration mode.