MES3000 Ethernet switch series 113
no ethernet cfm mep id
domain domain_name
service {vlan-id vlan_id |
name name | number
number}
Remove maintenance end point (MEP) from the interface.
Maintenance end point configuration mode commands
Command line request in domain configuration mode appears as follows:
console(config-if-cfm-mep)#
Table 5.115 —CFM end point (MEP) configuration mode commands
Disable maintenance end point (MEP).
Enable Continuty Check message transmission.
no continuty-check enable
Set CoS priority value for transmission of Continuty Check
messages.
delay: (2500..10000)
ms/2500 ms
Define the delay interval that should pass before the alarm
generation.
interval: (2500..10000)
ms/10000 ms
Define the time interval that should pass before the alarm reset.
alarm notification {all |
errorxcon |
remoteerrorxcon |
macremote-error-xcon |
xcon | none}
Enable notifications for the specific event types.
Event types:
- all—all DefRDI, DefMACStatus, DefRemote, DefError, DefXcon
events
- error-xcon—DefError and DefXcon events only
- remote-error-xcon—DefRemote, DefError, and DefXcon events
only
- mac-remote-error-xcon—DefMACStatus, DefRemote, DefError,
and DefXcon events only
- xcon—DefXcon event only
- none—notifications disabled
Privileged EXEC mode commands
Command line request in privileged EXEC mode appears as follows:
console#
Table 5.116 —Privileged EXEC mode commands
show ethernet cfm domain
[name]
Show information on the specific domain or all domains.
Show information on Continuity Check protocol errors.
show ethernet cfm
maintenance-points {local |
remote }
Show information on local or remote maintenance end points
(MEP).
show ethernet cfm mpdb
[domain-id { dns name |
name | name name| mac
mac_address number | null}]
name: (1..43)
characters;
mac_address: H.H.H or
H:H:H:H:H:H or
HHHH-H-H;
number: (0..65535)
Show information on maintenance intermediate points (MIP) for
the selected domain or all domains.
show ethernet cfm statistics
Show CFM statistics for all domains.