148 MES3000 Ethernet switch series
Table 5.161 —Description of results
Record creation date and time.
Quantity of data bytes (including bad packet bytes) received from the network (w/o
frame bits, but with checksum bits).
Quantity of packets received (including bad packets) during the record generation
period.
Quantity of good packets received during the record generation period, forwarded to
broadcast addresses.
Quantity of good packets received during the record generation period, forwarded to
multicast addresses.
Estimation of the physical layer average bandwidth for this interface during the record
generation period. Bandwidth is estimated up to the thousandth of one percent.
Quantity of packets received during the record generation period, with length from 64 to
1518 bytes inclusively, that have invalid checksum with integral byte quantity (checksum
verification errors—FCS) or with non-integral byte quantity (alignment errors).
Estimation of the collision quantity for this Ethernet segment during the record
generation period.
Quantity of packets received during the record generation period, with length less than
64 bytes (w/o frame bits, but with checksum bits), but formed correctly in other
respects.
Quantity of packets received during the record generation period, with length more than
1518 bytes (w/o frame bits, but with checksum bits), but formed correctly in other
respects.
Quantity of packets received during the record generation period, with length less than
64 bytes (w/o frame bits, but with checksum bits), that have invalid checksum with
integral byte quantity (checksum verification errors—FCS) or with non-integral byte
quantity (alignment errors).
Quantity of packets received during the record generation period, with length more than
1518 bytes (w/o frame bits, but with checksum bits), that have invalid checksum with
integral byte quantity (checksum verification errors—FCS) or with non-integral byte
quantity (alignment errors).
The quantity of detected events when the packets were dropped during the record
generation period.
Show the alarm signal summary table:
console# show rmon alarm-table
Index OID Owner
----- -------------------------- -------
1 1.3.6.1.2.1.2.2.1.10.1 CLI
2 1.3.6.1.2.1.2.2.1.10.1 Manager
Table 5.162 —Description of results
Index, the unique identifier of the record
User, that created the record.