MES3000 Ethernet switch series 163
Table 5.187 —Global configuration mode commands
optical-transceiver threshold
notify-interval interval
interval: (30..3600)/600
seconds
Define the minimum time interval between the generations of
SYSLOG/SNMP informational messages. Messages are generated
when optical line parameters fall outside of the allowable limits.
no optical-transceiver
threshold notify-interval
Set the interval default value.
Ethernet interface configuration mode commands
Command line request in Ethernet interface configuration mode appears as follows:
console# configure
console(config)# interface {gigabitethernet gi_port| tengigabitethernet
te_port}
console(config-if)#
Table 5.188 —Ethernet interface configuration mode commands
optical-transceiver threshold
action{parameter | all} {none |
syslog | snmp-trap}
parameter: (current,
input-power,
outputpower,
temperature, voltage)
Define the action (do not perform any actions, generate SYSLOG
message, generate SNMP trap) that should be executed when
the parameter falls outside of the allowable limits.
Default action is 'none'.
Possible parameter types
- current—transceiver supply current
- voltage—supply voltage
- input-power—receiving optical signal power
- output-power—transmitting optical signal power
- temperature—temperature.
optical-transceiver threshold
values parameter high-alarm
high-warning low-warning
lowalarm
parameter: (current,
input-power,
outputpower,
temperature, voltage)
Specify the threshold values which, when crossed, will cause
SYSLOG/SNMP message generation for the specific parameter.
- high-warning, low-warning—upper and lower limits for
warning message generation
- high-alarm, low-alarm—upper and lower limits for alarm
message generation
Allowable range of parameter values:
current: 0…131000 µA
input-power: -40000…8200 mdBm
output-power: -40000-8200 mdBm
temperature: -127…127 °C
voltage: 0…6550 000 µV
Threshold values should be specified in units mentioned above.
no optical-transceiver
threshold values parameter
Remove the threshold values specified by user for the specific
parameter. Default values are read from the transceiver during
the installation.
Command line request in EXEC mode appears as follows:
console>
Table 5.189 —Optical transceiver diagnostics command
show fiber-ports
opticaltransceiver [interface
{gigabitethernet gi_port |
tengigabitethernet te_port}]
[detailed]
gi_port: (1..8/0/1..24);
te_port: (1..8/0/1..4).
Show optical transceiver diagnostics results.
- detailed—detailed diagnostics, transceiver eeprom parameters.