Figure A-7: Loop Resistance: Active Non-IS Analog Output
%
$
$
$











A. Loop resistance [Ω]
B. Lift-off voltage [V]
Max Loop Resistance
(14)
= (20.3 – Lift-off Voltage)/Max Loop Current – 330 [Ω]
Figure A-8: Loop Resistance: Active IS Analog Output
%
$
$
$







A. Loop resistance [Ω]
B. Lift-off voltage [V]
Max Loop Resistance
(14)
= (19.5 – Lift-off Voltage)/Max Loop Current – 600 [Ω]
Reference Manual Specifications and reference data
00809-0100-2410 December 2019
Rosemount 2410 Tank Hub 119