2. The Volume Calculation function must be activated in order to enable advanced
Volume simulation. See Volume configuration for more information.
The volume calculation result is presented in input register IR4702, IR3400 (tank 1)
and in input register area starting with IR30000 (IR30148 for tank 1).
3. To simulate Observed Density the Hybrid Density function must be activated. See
Hybrid density configuration for more information.
The resulting Observed Density is available in input register IR3500 (tank 1). It is
also available in input register area starting with IR30000 (IR30116 for tank 1).
Service and troubleshooting Reference Manual
December 2019 00809-0100-2410
92 Reference Manual