Table 7-19: Compatibility between Firmware Version and Probe Type
Firmware
version
Probe type
Standard HP/HTHP
without R2
marking
HP/HTHP/C with
R2 marking
only
(1)
HTHP with
both R3 and
VC marking
Large coaxial
HP/C
R 2
R 2
R 2
R 2
R3
R3
Earlier than
1.A4
Yes Yes No No No
1.A4 Yes Yes
(2)
Yes No No
2.A2 - 2.F0 Yes Yes
(2)
Yes
(3)
No No
2.H0 -2.J0 Yes Yes
(2)
Yes
(3)
Yes
(4)
No
2.L3 or later Yes Yes
(2)
Yes
(3)
Yes
(4)
Yes
(1) The R2 marking is on the housing seal or the adapter as seen in the figure.
(2) Trim Near Zone function is required.
(3) When Dynamic Vapor Compensation is not used.
(4) The probe requires that Dynamic Vapor Compensation is activated in the device for full
functionality.
7.13.2
Check firmware and probe version
Procedure
1. Check the manufacturing date on the transmitter head label.
A. Manufacturing Date Before 080618 (YYMMDD)
2. Check the marking on the probe.
Reference Manual Service and troubleshooting