However, there are some restrictions for the standard and HP/C coaxial probes: Probes
over 4.1 ft. (1.25 m) can be cut up to 2 ft. (0.6 m). Shorter probes can be cut to the
minimum length of 1.3 ft. (0.4 m).
Flexible single lead probes can be cut to the minimum length of 3.3 ft. (1.0 m).
Minimum and maximum probe length
Probe type Probe length
Flexible single lead 3.3 to 164 ft. (1 to 50 m)
Rigid single lead (0.3 in./8 mm) 1.3 to 9.8 ft. (0.4 to 3 m)
Rigid single lead (0.5 in./13 mm) 1.3 to 19.7 ft. (0.4 to 6 m)
Segmented rigid single lead 1.3 to 32.8 ft. (0.4 to 10 m)
Flexible twin lead 3.3 to 164 ft. (1 to 50 m)
Rigid twin lead 1.3 to 9.8 ft. (0.4 to 3 m)
Coaxial 1.3 to 19.7 ft. (0.4 to 6 m)
Large coaxial 1.0 to 19.7 ft. (0.3 to 6 m)
Probe angle
0 to 90 degrees from vertical axis
Note
Models with QT option code should not be installed in angled probe installations.
Tensile strength
0.16 in. (4 mm) Flexible single lead SST: 2698 lb (12 kN)
0.16 in. (4 mm) Flexible single lead Alloy C-276: 1798 lb (8 kN)
0.16 in. (4 mm) Flexible single lead Alloy 400: 1124 lb (5 kN)
0.16 in. (4 mm) Flexible single lead Duplex 2205: 1349 lb (6 kN)
0.24 in. (6 mm) Flexible single lead SST: 6519 lb (29 kN)
Flexible twin lead SST: 2023 lb (9 kN)
Collapse load
0.16 in. (4 mm) Flexible single lead SST: 3597 lb (16 kN)
0.16 in. (4 mm) Flexible single lead Alloy C-276: 2023 lb (9 kN)
0.16 in. (4 mm) Flexible single lead Alloy 400: 1349 lb (6 kN)
0.16 in. (4 mm) Flexible single lead Duplex 2205: 1574 lb (7 kN)
0.24 in. (6 mm) Flexible Single Lead SST: 7868 lb (35 kN)
Reference Manual Specifications and reference data