Sideway capacity
• Rigid single lead/Segmented rigid single lead: 4.4 ft. lbf, 0.44 lb at 9.8 ft. (6 Nm, 0.2 kg
at 3 m)
• Rigid twin lead: 2.2 ft. lbf, 0.22 lb at 9.8 ft. (3 Nm, 0.1 kg at 3 m)
• Coaxial/Large coaxial: 73.7 ft. lbf, 3.7 lb at 19.7 ft. (100 Nm, 1.67 kg at 6 m)
A.3.10 Material exposed to tank atmosphere
Table A-18: Standard Probe (Operating Temperature and Pressure Code S)
Material of construction code Material exposed to tank atmosphere
1 (probe types 6A and 6B) 316L (EN 1.4404), 316
(1)
, Duplex 2507 (UNS S32750/EN 1.4410),
PTFE, PFA, and O-ring materials
1 (all other probe types) 316L (EN 1.4404), 316
(1)
, PTFE, PFA, and O-ring materials
2 and H Alloy C-276 (UNS N10276), PTFE, PFA, and O-ring materials
3 Alloy 400 (UNS N04400), Alloy K500, PTFE, PFA, and O-ring
materials
7 PTFE (1 mm PTFE cover)
8 PTFE, 316/316L (EN 1.4404), and O-ring materials
D Duplex 2205 (UNS S31803/EN 1.4462), Duplex 2507 (UNS
S32750/EN 1.4410), PTFE, PFA, and O-ring materials
(1) For flexible single/twin lead probes only.
Table A-19: HTHP Probe (Operating Temperature and Pressure Code H)
Material of construction code Material exposed to tank atmosphere
1 316L (EN 1.4404), 316
(1)
, Ceramic (Al2O3), Graphite, and Alloy
625
2 and H Alloy C-276 (UNS N10276), Ceramic (Al2O3), Graphite, and Alloy
625
D Duplex 2205 (UNS S31803/EN 1.4462), Ceramic (Al2O3),
Graphite, and Alloy 625
(1) For flexible single/twin lead probes only.
Specifications and reference data Reference Manual
April 2019 00809-0100-4530
304 Rosemount 5300 Level Transmitter