Table A-26: Rosemount 5301 and 5302 Level and/or Interface in Liquids Ordering Information
(continued)
KG ATEX, Canadian, IECEx Intrinsic Safety
KH USA, Canadian, IECEx Intrinsic Safety
KI
(17)
FISCO - ATEX, USA, Canadian Intrinsic Safety
KJ
(17)
FISCO - ATEX, USA, IECEX Intrinsic Safety
KK
(17)
FISCO - ATEX, Canadian, IECEX Intrinsic Safety
KL
(17)
FISCO - USA, Canadian, IECEX Intrinsic Safety
N1 ATEX Type n
N7 IECEx Type n
Options (include with selected model number)
Display
M1 Integral digital display ★
Communication
HR7 4–20 mA with digital signal based on HART 7 protocol ★
Hydrostatic testing
P1
(19)
Hydrostatic testing ★
Factory configuration
C1 Factory configuration (Configuration Data Sheet required with order, available at Emerson.com/
Rosemount)
★
Alarm limit configuration
C4 Namur alarm and saturation levels, high alarm ★
C5 Namur alarm and saturation levels, low alarm ★
C8
(20)
Low alarm (standard Rosemount alarm and saturation levels) ★
Welding documentation
(21)
Q66 Welding Procedure Qualification Record Documentation
Q67 Welder Performance Qualification Record
Q68 Welding Procedure Specification
Special certifications
Q4 Calibration Data Certification ★
Q8
(22)
Material Traceability Certification consistent with ISO10474-3.1:2013 / EN10204-3.1:2004 ★
QG GOST Primary Verification Certificate
Safety certifications
QS Prior-use certificate of FMEDA Data. Only available with HART 4-20 mA output (output code H). ★
QT Safety-certified to IEC 61508 with certificate of FMEDA data. Only available with HART 4-20 mA output
(output code H).
★
Reference Manual Specifications and reference data
00809-0100-4530 April 2019
Reference Manual 333