Table A-26: Rosemount 5301 and 5302 Level and/or Interface in Liquids Ordering Information
(continued)
KG ATEX, Canadian, IECEx Intrinsic Safety
KH USA, Canadian, IECEx Intrinsic Safety
KI
(17)
FISCO - ATEX, USA, Canadian Intrinsic Safety
KJ
(17)
FISCO - ATEX, USA, IECEX Intrinsic Safety
KK
(17)
FISCO - ATEX, Canadian, IECEX Intrinsic Safety
KL
(17)
FISCO - USA, Canadian, IECEX Intrinsic Safety
N1 ATEX Type n
N7 IECEx Type n
Options (include with selected model number)
Display
M1 Integral digital display
Communication
HR7 4–20 mA with digital signal based on HART 7 protocol
Hydrostatic testing
P1
(19)
Hydrostatic testing
Factory configuration
C1 Factory configuration (Configuration Data Sheet required with order, available at Emerson.com/
Rosemount)
Alarm limit configuration
C4 Namur alarm and saturation levels, high alarm
C5 Namur alarm and saturation levels, low alarm
C8
(20)
Low alarm (standard Rosemount alarm and saturation levels)
Welding documentation
(21)
Q66 Welding Procedure Qualification Record Documentation
Q67 Welder Performance Qualification Record
Q68 Welding Procedure Specification
Special certifications
Q4 Calibration Data Certification
Q8
(22)
Material Traceability Certification consistent with ISO10474-3.1:2013 / EN10204-3.1:2004
QG GOST Primary Verification Certificate
Safety certifications
QS Prior-use certificate of FMEDA Data. Only available with HART 4-20 mA output (output code H).
QT Safety-certified to IEC 61508 with certificate of FMEDA data. Only available with HART 4-20 mA output
(output code H).
Reference Manual Specifications and reference data
00809-0100-4530 April 2019
Reference Manual 333

Table of Contents

Other manuals for Emerson Rosemount 5300 Series

Related product manuals