2.11 Power
2.11.1 Power Generation Overview
The Mercury+ XU6 SoC module uses a 5 - 15 V DC power input for generating the on-board supply voltages
(0.72/0.85/0.9 V, 0.85/0.9 V, 0.9 V, 1.2 V, 1.8 V, 2.5 V, 3.3 V and 5.0 V). Some of these voltages (1.8 V, 2.5 V, 3.3
V) are accessible on the module connector.
Table 13 describes the power supplies generated on the module.
Voltage Voltage Rated Voltage Shut down Influences
Supply Name Value Current Source via PWR_EN PWR_GOOD
VCC_VTT 0.6 V
(DDR4 termination voltage)
3 A VCC_3V3 Yes Yes
VCC_INT 0.72/0.85 V/0.9 V
(PL core supply)
9 A VCC_MOD Yes Yes
VCC_PSINT 0.85 V/0.9 V (PS core supply) 6 A VCC_MOD Yes Yes
VCC_0V9 0.9 V
(MGT and VCU core supply)
6 A VCC_MOD Yes Yes
VCC_1V2 1.2 V 6 A VCC_MOD Yes Yes
VCC_BAT_FPGA 1.5 V 10 mA VCC_BAT No No
VCC_1V8 1.8 V 3 A VCC_MOD Yes Yes
VCC_2V5 2.5 V 0.5 A VCC_3V3 Yes No
VCC_3V3 3.3 V 6 A VCC_MOD No Yes
VCC_5V0 5.0 V 0.15 A VCC_MOD No No
Table 13: Generated Power Supplies
In the standard configuration, the PL core supply is 0.85 V. For custom product configurations, in which a
speedgrade -3E MPSoC device is equipped, an assembly option is available to switch the PL core operating
voltage to 0.9 V. Similarly, in situations in which a speedgrade -2LE or -1LI device is used, an assembly option
is available to switch the PL core operating voltage to 0.72 V.
In the standard configuration, the PS core supply is 0.85 V. For custom configurations, in which a speedgrade
-3E MPSoC device is equipped, an assembly option is available to switch the PS core operating voltage to
0.9 V.
Please refer to the Enclustra Module Pin Connection Guidelines for general rules on the power pins [10].
2.11.2 Power Enable/Power Good
The Mercury+ XU6 SoC module provides a power enable input on the module connector. This input may
be used to shut down the DC/DC converters and LDOs for 0.6 V, 0.72/0.85/0.9 V, 0.85/0.9 V, 0.9 V, 1.2 V, 1.8
V and 2.5 V. The list of regulators that can be disabled via PWR_EN signal is provided in Section 2.11.1.
D-0000-464-001 29 / 58 Version 02, 21.07.2021