Cerabar S/Deltabar S Description of parameters (ToF Tool)
Endress+Hauser 147
INSERT PIN NO
Entry
For entering a code to lock or unlock operation.
!
Note!
• The -symbol on the on-site display indicates that operation is locked. Parameters
which refer to how the display appears, e.g. LANGUAGE and DISPLAY CONTRAST
can still be altered.
• If operation is locked by means of the DIP-switch, you can only unlock operation again
by means of the DIP-switch. If operation is locked by means of the on-site display or
remote operation e.g. ToF Tool, you can unlock operation again by means of the on-
site display or using remote operation.
→ See also Operating Instructions BA301P (Deltabar S) or BA302P (Cerabar S), Section
5.6 "Locking/unlocking operation".
Options:
• Lock: enter a number between 0...9999 which is ≠100.
• Unlock: enter the number 100.
Factory setting:
100
HistoROM AVAIL.
Display
Indicates whether the optional HistoROM®/M-DAT memory module is connected to the
electronic insert.
→ See also Operating Instructions BA301P (Deltabar S) or BA302P
(Cerabar S), Section 5.4 "HistoROM
®
/M-DAT (optional)".
Options:
•Yes (HistoROM
®
/M-DAT is attached to the electronic insert)
• No (HistoROM
®
/M-DAT is not attached to the electronic insert)
HistoROM CONTROL
Selection
For selecting the direction for copying the data.
→ See also Operating Instructions BA301P (Deltabar S) or BA302P
(Cerabar S), Section 5.4 "HistoROM
®
/M-DAT (optional)".
Prerequisite:
•A HistoROM
®
/M-DAT is attached to the electronic insert
(HistoROM AVAIL. = yes)
Options:
• Abort
•HistoROM → Device
• Device → HistoROM
Factory setting:
Abort (if HistoROM
®
/M-DAT is connected to the electronic insert)
ToF Tool, Table 25: OPERATING MENU → OPERATING
Parameter name Description