Description of device parameters (operating menu) Levelflex FMP51, FMP52, FMP54
138 Endress+Hauser
Description
Defines the unit of the linearized value.
Selection
• Free text
•
t
• lb
• ton
• kg
• impGal
• UsGal
• cf
• cm
3
• dm
3
• m
3
• hl
• l
• %
Factory setting
%
Additional information
The selected unit is only used to be indicated on the display. The measured value is not
transformed according to the selected unit.
Free text
Navigation
Setup ® Advanced setup ® Linearization ® Free text
Condition
Only visible for Unit lienarized = Free text.
Description
Definiton of the unit
Input range
Up to 32 alphanumerical characters (letters, numbers, special characters)
Factory setting Free text
Maximum value
Navigation
Setup ® Advanced setup ® Linearization ® Maximum value
Condition
Only visible if one of the following linearization types has been selected:
•
Linear
• Pyramid bottom
• Conical bottom
• Angled bottom
• Horizontal cylinder
• Sphere
Description
Definition of the maximum content of the vessel (100%), as measured in the Unit linearized.
Input range
-50000 ... +50000