10 Technical data Promag 53 PROFIBUS-DP/-PA
170 Endress+Hauser
Tri-clamp for ODT
1.4404 / 316L
5*H**-1***********
DN di G D L LK
[mm] [inch] [mm] [mm] [mm] [mm] [mm]
40 1 1/2" 34.8 50.4 92 68.6 71.0
50 2" 47.5 63.9 105 68.6 83.5
65
60.2 77.4 121 68.6 100.0
80 3" 72.9 90.9 147 68.6 121.0
100 4" 97.4 118.9 168 68.6 141.5
Fitting length = (2 x L) + 140 mm (DN 40...65) / + 200 mm (DN 80...100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 158)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-004
Coupling DIN 11851
1.4404 / 316L
5*H**-2***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 38 Rd 65 x 1/6" 92 72 71.0
50 50 Rd 78 x 1/6" 105 74 83.5
65 66 Rd 95 x 1/6" 121 78 100.0
80 81 Rd 110 x 1/4" 147 83 121.0
100 100 Rd 130 x 1/4" 168 92 141.5
Fitting length = (2 x L) + 140 mm (DN 40...65) / + 200 mm (DN 80...100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 158)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-001
Coupling DIN 11864-1
1.4404 / 316L
5*H**-3***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK
[mm]
40 38 Rd 65 x 1/6" 92 71 71.0
50 50 Rd 78 x 1/6" 105 71 83.5
65 66 Rd 95 x 1/6" 121 76 100.0
80 81 Rd 110 x 1/4" 147 82 121.0
100 100 Rd 130 x 1/4" 168 90 141.5
Fitting length = (2 x L) + 140 mm (DN 40...65) / + 200 mm (DN 80...100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 158)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-006
Flange DIN 11864-2 Form A:
1.4404/316L
5*H**-4***********
DN
[mm]
di
[mm]
G
[mm]
D
[mm]
L
[mm]
LK1
[mm]
LK2
[mm]
40 38 82 92 64 71.0 65
50 50 94 105 64 83.5 77
65 66 113 121 64 100.0 95
80 81 133 147 98 121.0 112
100 100 159 168 98 141.5 137
Fitting length = (2 x L) + 140 mm (DN 40...65) / + 200 mm (DN 80...100)
If pigs are used for cleaning, it is essential to take the inside diameters of measuring tube (Page 158)
and process connection (di) into account.
F06-xxHxxxxx-06-09-07-xx-007