Waterpilot FMX21 Description of device parameters
Endress+Hauser 107
Write permission No write permissions. Parameter is read only.
Description The secondary value is displayed.
Third value is
Write permission No write permissions. Parameter is read only.
Description Indicates which measured value is transmitted via the HART protocol as the third process
value. The process value is configured via HART command 51.
Factory setting "Pressure" measuring mode: "Sensor pressure"
"Level" measuring mode, "Linear" lin. mode: "Corrected press."
"Level" measuring mode, "Activate table" lin. mode: "Meas. pressure"
Display Depending on the selected measuring mode, the following measured values can be
displayed:
"Meas. pressure"
"Sensor pressure"
"Corrected press."
"Pressure after damping"
"Sensor temp."
"Level before Lin"
"Tank content"
"Process density" (corrected)
Third value is
Write permission No write permissions. Parameter is read only.
Description The third value is displayed.
4th value is
Write permission No write permissions. Parameter is read only.
Description Indicates which measured value is transmitted via the HART protocol as the fourth process
value. The process value is configured via HART command 51.
Factory setting "Pressure" measuring mode: "Sensor temp"
"Level" measuring mode, "Linear" lin. mode: "Sensor temp."
"Level" measuring mode, "Activate table" lin. mode: "Sensor temp."
Display Depending on the selected measuring mode, the following measured values can be
displayed: