5.6 Mounting the terminal box
The optional terminal box is mounted using four screws (M4). For the dimensions of the
terminal box, please see the Technical Information TI00431P/00/ EN, "Mechanical
construction" section (see also: www.de.endress.com → Downloads → Media Type:
Documentation).
5.7 Mounting the TMT182 temperature head transmitter
with terminal box
1
3
2
6
5
4
3
CLOSE
90°
OPEN
90°
Warning:
Avoid electrostatic charge in explosive atmosphere.
See instructions
Terminal Box for FMX21
1
2
3
4
5
A0018813
1 Mounting screws
2 Mounting springs
3 TMT182 temperature head transmitter
4 Circlips
5 Terminal box
Only open the terminal box with a screwdriver.
L
WARNING
Risk of explosion!
The TMT182 is not designed for use in hazardous areas.
5.7.1 Mounting the temperature head transmitter:
1. Guide the mounting screws (item 1) with the mounting springs (item 2) through the
hole in the temperature head transmitter (item 3)
2. Secure the mounting screws with the circlips (item 4). Circlips, mounting screws and
springs are included in the scope of delivery for the temperature head transmitter.
3. Screw the temperature head transmitter into the field housing tightly. (width of
screwdriver blade max. 6 mm (0.24 in))
NOTICE
Avoid damage to the temperature head transmitter.
Do not overtighten the mounting screw too.