6.4.2.9 Installation mode
To enter the Installation mode, click on Installation in the menu bar:
Installation mode enables the operator to control the system manually in all aspects, to solve
unexpected or difficult situations. In fact, it’s an emergency mode.
The installation mode differs from normal operation on the following:
All safety measures are switched off
No automatic levelling is applied to the main jacks (“hysteresis”).
Main jacks can be selected individually:
Installation mode is only applicable for manual mode, not for automatic mode.
Do not execute an operation in installation mode.
Hazard
Operating the system in Installation mode may causes potential hazards to
personnel and damage to the system, due to the fact that all safety
precautions are switched off.
Hazard
For the JS500, the main cylinders may not be extended when only the End
Barrel is in the system and is not locked. When failing to follow this requirement
the system will be damaged and causes potential hazards to personnel.
main jacks 1,2,3,4