Section 2 — Algorithms
ENSONIQ DP/4+ Reference Manual 95
15 — Gate Release Time Range: 1ms to 10.0s
Determines how long it takes for the gate to be fully released after the input signal drops below
the threshold level. Lower settings yield a quick gate.
16 — Pre-EQHighPass Cutoff Range: 4 to 1000 Hz
Filters out the low frequencies. The higher the value, the less low frequencies pass through. This
parameter is used to increase brightness.
17 — Mod1 Source 21 — Mod2 Source
18 — Mod1 Destination 22 — Mod2 Destination
19 — Mod1 Param Range Min 23 — Mod2 Param Range Min
20 — Mod1 Param Range Max24 — Mod2 Param Range Max
See the descriptions under the Algorithm Modulators in the beginning of this section.