Section 2 — Algorithms
56 ENSONIQ DP/4+ Reference Manual
07 — Exp Release Range: 1ms to 10.0s
Determines how long it takes for the expansion to be fully deactivated after the input signal rises
above the threshold level. This is generally longer than the attack time.
08 — Exp Noise Gate Off Below Range: -96 to +00 dB
This parameter sets the lower threshold level at which the noise gate shuts off the audio.
09 — Comp Noise Gate On Above Range: -96 to +00 dB
Sets the upper threshold level at which the noise gate passes audio. This second parameter
provides hysteresis.
10 — Bass Fc Range: 0 to 1000 Hz
Sets the cutoff frequency of the lower frequency band shelving filter.
11 — Bass EQ Gain Range: -48 to +24 dB
Sets the amount of boost or cut applied to the low shelving filter.
12 — Treble Fc Range: 01KHz to 16KHz
Sets the cutoff frequency of the upper frequency band high shelving filter.
13 — Treble EQ Gain Range: -48 to +24 dB
This parameter sets the amount of boost or cut applied to the high shelving filter.
14 — EQ Input Level Trim Range: -24 to +00 dB
Adjusts the input volume of the EQs, to eliminate the possibility of clipping boosted signals.
15 — Mod1 Source 19 — Mod2 Source
16 — Mod1 Destination 20 — Mod2 Destination
17 — Mod1 Param Range Min 21 — Mod2 Param Range Min
18 — Mod1 Param Range Max22 — Mod2 Param Range Max
See the descriptions under the Algorithm Modulators at the beginning of this section.