Configuring Switches in a Stack
SecureStack C2 Installation Guide 3-13
About SecureStack C2 Switch Operation in a Stack
TheSecureStackC2productsarestackableswitchesthatcanbeadaptedandscaledto
helpmeetyournetworkneeds.Theseswitchesprovideamanagementplatformand
uplinktoanetworkbackboneforastackedgroupofuptoeightSecureStackswitches.
Onceinstalledinastack,theswitchesbehaveand perform
asasingleswitch.Assuch,
youcanstartwithasingleswitchandaddmoreswitchesasyournetworkexpands.You
canalsomixdifferentproductsinthefamilyinasinglestacktoprovideadesired
combinationofporttypesandfunctionstomatchtherequirementsofindividual
applications.Inallcases,astackofswitchesperformsasonelargeproduct,andis
managedasasinglenetworkentity.
WhenswitchesareinstalledandconnectedasdescribedbackinConnectingHighSpeed
StackingCablesonpage 311,thefollowingoccursduringinitialization:
•Theswitchthatwillmanagethestack
isautomaticallyestablishedandisreferredtoas
theManagerswitch.
•AllotherswitchesareestablishedasMemberswitchesinthestack.
•Thehierarchyoftheswitchesthatwillassumethefunctionofbackupmanagerisalso
determinedincasethecurrentmanagermalfunctions,ispowereddown,oris
disconnectedfrom
thestack.
•Theconsoleportonthemanagerswitchremainsactiveforoutofband(local)switch
management,buttheconsoleportoneachmemberswitchisdeactivated.Thisenables
youtosettheIPaddressandsystempasswordusingasingleconsoleport.Noweach
switchcanbeconfigured
locallyusingonlythemanagersconsoleport,orinband
usingaremotedeviceandtheCLIsetofcommandsdescribedinthissection.For
proceduresusedforvarioustypesofconnectionstotheConsoleport,referto
ConnectingtoConsolePortforLocalManagementonpage 317.
Onceastack
iscreated(morethanoneswitchisinterconnected),thefollowingoccurs:
1. Switch(unit)IDsarearbitrarilyassignedonafirstcome,firstservedbasis.
2. SwitchIDsaresavedagainsteachmodule.Then,everytimeaboardispowercycled,
itwillinitializewiththesameswitchID.Thisisimportantforport
specific
information(forexample:ge.4.12isthe12thGigabitEthernetportonswitch#4).
3. Themanagementelectionprocessusesthefollowingprecedencetoassigna
managementdevice:
a. Previouslyassigned/electedmanagementswitch
b. Managementassignedpriority(values115)
c. Hardwarepreferencelevel
d. HighestMACAddress