EPSON AcuLaser C9200N Revision D
Troubleshooting Service Call Error 111
Confidential
E702
Standard cassette Elevator failure
The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been
started.
p.127E703
Optional Cassette1 Elevator failure
The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been
started.
E704
Optional Cassette2 Elevator failure
The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been
started.
E900
Flash ROM write error
Flash ROM writing is found faulty during a check. p.128
E901
RTC failure
The correct access to the RTC Board is failed during access. p.128
E998
Engine communication error
The correct access between the Controller Board and the Mechanical Control Board are failed during access. p.128
Table 3-16. Error Code List