EasyManua.ls Logo

Epson Aculaser C9200N - Page 190

Epson Aculaser C9200N
441 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C9200N Revision D
DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 190
Confidential
5. Remove the PH Unit (Black) according to the following procedure.
1. Move the front side of the PH Unit to left a little, and remove the Boss [9] from the locating
hole [10].
2. Lift up the front side of the PH Unit a little.
3. Remove the Boss [11] at the rear side of the PH Unit from the locating hole [12].
4. Remove the PH Unit [14].
6. Follow the same procedures to remove all PH Units.
C H E C K
P O I N T
Since the back of the PH Unit is pushed to the right with the two Plate Springs [13],
remove it by tilting the backside of the PH Unit to the left as shown in the figure
above.
[14]
4037F2C111DB
[11]
[13]
[12]
4038F2C110DA
[9]
[10]
<Assembling procedure of the PH Unit>
1. Fit the back of the PH Unit [1] to the Plate Spring [2] of installation plate.
2. Push the PH Unit [3] along the right side line of PH Unit installation plate all the way and fit
it into the Plate Spring [4].
3. Make sure that the two Bosses [5] at front and rear side of the PH Unit fit in the locating
hole [6].
4037F2C113DB
[1]
[2]
4037F2C114DA
[3]
[5]
[6]
[5]
[6]
[4]