OPERATING PRINCIPLES Operating Principle of Main Unit Mechanism 65
Confidential
WASTE TONER NEAR-FULL/FULL DETECTION CONTROL
Waste Toner Detection Mechanism
To prevent false detection, an Agitation Screw is mounted in the Waste
Toner Collector so that the waste toner is accumulated in the bottle
evenly.
The Waste Toner Full Sensor (PC8) detects the area where the visor A
mounted on the shaft of the Toner Conveying Screw overlaps with the
visor B. (As the amount of the waste toner increases, the load for the
screw to rotate will increase. The period of time the Light Shield Plate
blocks the Waste Toner Full Sensor (PC8) will then become shorter).
Figure 2-47. Waste Toner Detection Mechanism 1
Figure 2-48. Waste Toner Detection Mechanism 2
4038T2C175AA
4038T2C174AA
Waste Toner Collector Agitator Screw
Light Shield Plate A
Light Shield Plate B
Waste Toner Full Sensor (PC8)
Torsion Coil Spring
4038T2C176AA
Light Shield Plate A
Light Shield Plate B
Waste Toner Full Sensor (PC8)
4038T2C178AA
4038T2C177AA
Waste Toner Empty
Waste Toner Full
4038T2C116AA