Installation Checklist
Go through the following checklist to ensure you have installed the appliance correctly
□ Correctly sized cavity to suit your fascia and flue configuration
□ Correct clearances to combustibles and mantles around the fascia
□ An electrical isolating switch to the appliance, accessible after finished installation
□ Correctly sized gas supply with a pressure test point, ensuring adequate supply with all other
gas appliances in the dwelling running
□ A weather-tight installed horizontal or vertical powerflue terminal with clearance as
specified by AS/NZ5601.1
□ If chosen, reasonable access to the outside face of the horizontal powerflue wall terminal
for maintenance purposes and flue attached to the rear of the horizontal powerflue wall
terminal leading back to the appliance (and similar for vertical powerflue terminals)
□ The electrical cable from the powerflue terminal attached correctly and run back to the
appliance cavity in an electrically safe manner
□ The appliance fixed to the cavity base
□ The appliance plugged into a mains electricity supply
□ All gas joints and pressure points leak tested, and suitable leak detection solution and drop
tests completed on gas pipework
□ Fuel bed correctly installed
□ Glass correctly fitted
□ Operated the fire and verified that it lights reliably and safely
□ Appliance functions checked, including thermostat operation, Eect Only, and Fan Boost
□ Data label marked up with correct gas type, and dated by installer if converted during
installation