B
ACDEFGSERVICE
S3 Cleaning the Fuel bed, Fascia, and Glass
ALWAYS USE GLOVES WHEN HANDLING THE FASCIA AND GLASS.
The outside of an Escea Fascia must only be cleaned with a soft microfibre cloth. If heavier cleaning is
required for the likes of grease or stubborn fingerprint removal we recommend the use of a dedicated
stainless steel cleaner for stainless steel fascias or warm soapy water for powder coated fascias.
NEVER RUB THE FASCIA.
For Stainless Steel Fascias:
1. Ensure that the Gas Fireplace is o and that the fascia is cold to the touch.
2. Using the gloves provided with your fascia, a stainless steel cleaner and a clean cloth, apply a small
amount of cleaner to the cloth and wipe the fascia with even, straight strokes.
3. Make sure your strokes follow the direction of the grain or brush finish. Wiping across the grain can
leave small scratches.
4. The cleaner may leave a very fine film over the fascia, ensure this film is distributed evenly.
5. If the film is applied too heavily and is quite visible, you can remove the excess by gently wiping dry
with a microfibre cloth. Ensure your strokes still follow the direction of the grain or brush finish.
6. Ensure that no film is applied to the glass of your Escea Gas Fireplace. If applied accidentally, wipe
o with an absorbent microfibre cloth.
For Powder Coated Fascias:
1. Ensure that the Gas Fireplace is o and that the fascia is cold to the touch.
2. Using the gloves provided with your fascia, gently clean the fascia with a cloth and warm soapy
water.
3. Wipe o with an absorbent microfibre cloth.
This is a service procedure that will need to be carried out whenever soot builds up on fuelbeds and/or
inside of glass.
If soot build up becomes excessive or regular then one of the following actions may be required:
• Reset gas pressure- pressure may be too high;
• Reposition fuelbed- check with specific fuelbed
instructions for details;
• Clear any blockage from primary aeration port of
burner;
• Check flue tube is not damaged or disconnected;
• Check exhaust fan is operating and cowl is not blocked
in any way.
Step 1: Remove fascia panel (if fitted) by pulling it from the wall.
Step 2: Remove the glass. Using the supplied 3mm Allan Key (hex drive) unscrew the bolts
around the glass retainer.
Take care that the glass and frame do not fall forward at this stage.
This is a two person lift.