IP Server 900 Programming Manual Function 3: Station programming
F.8
ESI Presence Management remote IP RFID Reader assignment
Important: Before starting this programming, be sure you know the IP address the remote IP RFID Reader will be
using at its remote site, because you have to enter this information in this procedure.
If necessary, consult the ESI Presence Management Installation Manual (ESI # 0450-0792).
1. Enter the extension number of the IP RFID Reader to be programmed and press # to continue.
STATION PROG
EXT: 115
2. Use the scroll keys to select REMOTE IP READER and press # to continue.
X115 TYPE
REMOTE IP READER
3. Now you’ll enter the remote IP RFID Reader’s MAC address, which appears on the second line of the
IP RFID Readers display when the device is powered-up. The MAC address is a 12-character
alphanumeric address, the first six characters of which will always be 00 30 4D. Enter the complete 12-
character alphanumeric address. If programming using an ESI desktop IP phone, use the first six
programmable feature keys to enter the letters A, B, C, D, E, or F, respectively.
X115 MAC ADDRESS
>
4. Now you’ll enter the IP address that the IP RFID Reader will be using at its remote site.
Enter this address in dotted-quad notation (for example, 192.168.1.3) by using the # key as the period
between octets. The remote RFID Reader must be on the same subnet as the LAN interface of the
gateway device (cable modem, router, etc.). For example: if the LAN interface’s IP address is
192.168.210.1 and its subnet mask is 255.255.255.0, the first three octets of the phone’s address must
be 192.168.210 and its last octet between 2 and 254.
X115 IP ADDRESS
0.0.0.0
5. Enter the valid subnet mask of the gateway device to which the remote IP RFID Reader will be
connected.
Range: 128.0.0.0 through 255.255.255.252. Default: 0.0.0.0.
X115 IP MASK
0.0.0.0
6. Enter the IP address of the remote IP RFID Reader’s gateway i.e., the LAN interface of the gateway
device at the remote site. The RFID Reader must be on the same subnet as the LAN interface of the
remote gateway.
X115 GATEWAY IP
0.0.0.0