EXCELL PRECISION CO., LTD
PW Service Manual SME300000016
18
NOTE 6
(o) (p) (q) (r) (s)
(o) ⇒ Minimum division
Parameter description:
(p) ⇒ Decimal point position
Parameter description:
(q) ⇒ Weight unit displayed
Parameter
oz GN dwt ct
Notation
system
10
10 16 10 10 10 10
symbol kg
lb lb
Icon 7
indication
Icon 6
(r) ⇒ Scale change point (Input the parameter 0, 1, 2, or 3)
Parameter description:
0 ⇒ full range
1 ⇒ full range
2 ⇒ dual range (changes at 1/2 of full scale)
3 ⇒ triple range (changes at 1/6 of full scale and 2/3 of full scale)
(s) ⇒ Save the weight units at preferred positions (no more than the number of set
weight units)
Parameter description:
1 ⇒ the first position (the weight calibration unit)
2 ⇒ the second position
3 ⇒ the third position
4 ⇒ the fourth position
5 ⇒ the fifth position
Decimal system:
0 ⇒ 0
1 ⇒ 0.0
2 ⇒ 0.00
3 ⇒ 0.000
4 ⇒ 0.0000
5 ⇒ 0.00000
Hexadecimal notation system:
Input 1, 2, 4, or 8 as the
minimum division for the
Hexadecimal notation syst
0 ⇒ 0._0
1 ⇒ 0._0.0
2 ⇒ 0._0.00
3 ⇒ 0._0.000
Decimal system:
Input 1, 2, or 5 as the
minimum division for the