EXCELL PRECISION CO., LTD
PW Service Manual SME300000016
27
Using
ON/ZERO
or
UNITS
to enter
Using
ON/ZERO
or
UNITS
to enter
Using
ON/ZERO
or
UNITS
to enter
2-4-1 Environment parameters
4 If parameters are changed in , then will be revised automatically
ON/ZERO
key ⇒ Step Up key
(Selects number 0,1,2,3,4,5,6,7,8,9)
UNITS
key ⇒ Step Down key
(Selects number 0,1,2,3,4,5,6,7,8,9)
TARE
key ⇒ Right key, flashing digit move to the right
NET/GROSS
key ⇒ Left key, flashing digit move to the left
Press
TARE
Return to zero point
Using
ON/ZERO
or
UNITS
to enter
Default = 0
0 ⇒ show all 5 ⇒ within 5 d
1 ⇒ within 1 d 6 ⇒ within 6 d
2 ⇒ within 2 d 7 ⇒ within 7 d
3 ⇒ within 3 d 8 ⇒ within 8 d
4 ⇒ within 4 d 9 ⇒ within 9 d
4 Weight value must over 1/3 full scale
Stabilization range
Display shows the current setting
Filter setting
Display shows the current setting
Press
TARE
to exit the
environment parameters
Enter “00”
Return to zero
The display shows the current setting
Weighing Filter setting
Use
ON/ZERO
or
UNITS
keys to input the
parameters. Default setting = 5
Range 0 ~ 9, the larger the number, the
faster the filter response. Fast response
could lead to display weight instability.
Stabilization range
Use
ON/ZERO
or
UNITS
keys to input
the parameters. Default setting = 0
Range 0 ~ 9, the larger the number the
more stable the weight.