Excell PW - 2-2-2 Manufacturing Location Gravity Setting (CAL02)

Excell PW
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EXCELL PRECISION CO., LTD
PW Service Manual SME300000016
22
Press the
TARE
key
Press the
TARE
key
Press the
TARE
key
Displays the gravity
value set previously
Re-set the gravity
value
Factory: Taipei
Factory: shanghai
Factory: others
NOTE
NOTE
Press the
TARE
key to
complete the gravity setting
2-2-2 Manufacturing Location Gravity Setting
n The gravity value is set between that at the equator and the polar regions.
Gravity value at the equator G
E
= 9.7803184558 m/sec
2
Gravity value at the polar regions G
P
= 9.8321772792 m/sec
2
Taipei 9.78914 m/sec
2
Shanghai 9.79585 m/sec
2
NOTE:
Use
ON/ZERO
or
UNITS
key
To choose which factory
.
.
ON/ZERO
key Increment number by 1
UNITS
key Decrement number by 1
TARE
key Move cursor one place to the right
NET/GROSS
key Move cursor one place to
the left
Press the
TARE
key
Press the
TARE
key
Input 00