Command Format C
Host Command+ Data
Slave Command+ Data
Write weight comparison setting value WS™™££XXXXXX
™™: Groups(00 ~ 09) ££: Setting Items XXXXXX: Setting Value
HI Write HI setting value
LO Write LO setting value
Note : ™™ (Group) is various depended on different models
00 The first group
01 The second group
02 The third group
EX:
WS00HI001000CR><LF Write HI setting value
ANS:
WS00HI001000CR><LF
Command Format D
Host Data
Slave
Value (e.g. Price)
Position of
decimal point
1 2 3 4 5 6 1
CR LF
When the SI-132 receives this data format, it will transfer the data and display it on
its LCD.
Note: The function is effective, when the weight value is over 0.
4 Error messages:
E1: Wrong command
E2: Command format error (Wrong parameters)
E3: Command not recognised
˙