IEEE 488.2 and Specific Command Reference
438 FTB-2/FTB-2 Pro and FTB-4 Pro
Specific Commands
Seconds:
The program data syntax for <Seconds> is
defined as a <DECIMAL NUMERIC PROGRAM
DATA> element.
The <Second> is rounded to the resolution of
the clock. It ranges from 0 to 60. A value of 60 is
allowed since rounding may cause a number
greater than 59.5 to be rounded to 60. When this
element is rounded to 60 it shall be set to 0 and
the minute value incremented. Any other carries
shall be rippled through the date.
Example(s) SYST:TIME 12,47,29
See Also SYSTem:TIME?
:SYSTem:TIME