67
NO-LOAD PERFORMANCE
z Disconnect the magneto lead wire coupler.
z Start the engine and keep it running at 5000r/min.
z Using a pocket tester, measure the AC voltage between
the white and red tracer lead wire and ground. If the
tester reading is as follows, magneto is in good
condition.
Standard no-load performance: more than 65v(AC)AT
5000R/MIN.
STATOR COILS
Inducing coils
Use procket tester to measure the resistance between the lead
wire and ground. If the resistance checked is not correct,
replace the coil.
Rregulator/rectifier
Disconnect the lead wire couple.
Using the pocket tester᧤ 1KQ RANGE᧥, measurethe
resistance between the terminals as shown in the following
table. If the resitance checked is incorrect, replace the
regulator/rectifier.
UNIT: KQ
NOTES᧶
Including the components such as
transistor,capacitance, regulator diode and so on, so tested
resistance may be different from actual resistance.
Standard
resistance
W/R-GROUND 0.6-1.1Q
W/R-GROUND 0.5-0.8 Q