BATTERY
SPECIFICATIONS
Type designation YB4L-B
Capacity 12V 4Ah
Standard electrolyte 1.28(20)
INITIAL CHARGING
FILLNG ELECTROLYTE
Remove the aluminum tape sealing the battery electrolyte filler holes.
Remove the caps ཱ
NOTE
* After filling the electrolyte completely,use the removed cap as
the sealed caps of battery-filler holes.
* Do not remove or pierce the sealed areas of the electrolyte container.
Insert the nozzles of the electrolyte container into the battery`s
electrolyte filler holes,holding the container firmly so that it
doer not fall.Take precaution not to allow any of the fluid to
spill.
Make sure air bubbles are coming up each electrolyte container,and
leave in the positon for about more than 20 minutes.
Test the battery after the filling process. If necessary charge the
battery about 20 minutes with the charger.