4 Push the power supply in until the latch snaps into place.
Caution
Do not slam the power supply into the chassis.
Figure 175: Installing a 750 W AC Power Supply in an EPS-C2 Chassis
Note
If power supplies are not installed in all three slots, be sure to install a cover over each
unoccupied slot. Unoccupied slots must always be covered to maintain proper system
ventilation and EMI levels.
Repeat the procedure to install each additional power supply.
Connecting Redundant Power Cables for the EPS-C2 Chassis
The EPS-C2 chassis can use up to five 2x7-pin redundant power connectors, shown in Figure 176, which
connect the power supply to ExtremeSwitching X440-G2 and X620 switches.
Figure 176: EPS-C2 2x7 Pin Redundant Power Cable with Connector Key Tab
Installing External Power Supplies
ExtremeSwitching and Summit Switches: Hardware Installation Guide 229

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extreme Networks ExtremeSwitching X440-G2 Series and is the answer not in the manual?

Extreme Networks ExtremeSwitching X440-G2 Series Specifications

General IconGeneral
Form FactorRack-mountable
VLAN SupportYes
Humidity5% to 95% non-condensing
ModelX440-G2 Series
Port TypeGigabit Ethernet
Switching Capacity176 Gbps
Forwarding Rate131 Mpps
StackingYes, up to 8 switches
Layer SupportLayer 2/3
Operating Temperature0°C to 50°C
Product TypeSwitch
Jumbo Frames9216 bytes
AC Power Supply100-240 VAC, 50-60 Hz
Storage Temperature-40°C to 70°C
Port Configuration24 or 48 ports
Power over Ethernet (PoE)Optional

Related product manuals